Abstract

At the IMKF, eight different elastomer compounds with different polymer compositions were examined for their demolding characteristics and mold fouling. Ten demolding cycles were carried out for each compound and the fouling of the mold was photo-technical recorded after ten demolding cycles. The used polymer composition does not seem to have any significant influence. However, the components of the compound have a significant influence on the friction characteristics while removing of the vulcanizate from the mold. Crosslinking that begins very early has an initiating influence on mold fouling. The measurable fluctuations in the maximum demolding force that occur could correlate with the internal friction of the polymer with the filler.