Abstract

To evaluate how different polishing techniques and coffee thermal cycling affect the surface roughness and stainability of additively and subtractively manufactured resins used for definitive prostheses. Two additively manufactured composite resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 90 rectangular-shaped specimens (14 × 12 × 1mm) (n= 30). After baseline surface roughness (Ra) measurements, specimens were divided into three groups based on the polishing technique; conventional polishing with a 2-stage polishing kit (CP) and surface sealant application (Optiglaze, OG or Vita Akzent LC, VA) (n= 10). After polishing, specimens were subjected to 10,000 cycles of coffee thermal cycling. Ra and color coordinate measurements were performed after polishing and after coffee thermal cycling. Color difference (ΔE00) was calculated. Scanning electron microscope images were taken at each time interval. Kruskal-Wallis or 1-way analysis of variance (ANOVA) were used to evaluate Ra of materials within each polishing-time interval pair and different polishing techniques within each material-time interval pair, while Friedman or repeated measures ANOVA were used to evaluate Ra at different time intervals within each material-polishing pair. ΔE00 was assessed with 2-way ANOVA (α= 0.05). Other than VA-after polishing (p= 0.055), tested materials had significantly different Ra within each polishing-time interval pair (p ≤ 0.038). When Ra differences among different polishing techniques within each material-time interval pair were considered, CS had differences after coffee thermal cycling, CT had differences before polishing and after coffee thermal cycling, and VS had differences within each time interval (p ≤ 0.038). When Ra differences among different time intervals within each material-polishing pair were considered, significant differences were observed among all pairs (p ≤ 0.016), except for CS-VA (p= 0.695) and VS-VA (p= 0.300). ΔE00 values were affected by material and polishing technique interaction (p= 0.007). Ra of CS was similar to or lower than the Ra of other materials, regardless of the time interval or polishing technique. CP mostly led to lower Ra than other polishing techniques, whereas VA resulted in a high Ra regardless of the material-time interval pair. Polishing reduced the Ra, while coffee thermal cycling was found to have a small effect. Among tested material-polishing pairs, only CS-VA had moderately unacceptable color change when previously reported threshold values were considered.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.