Abstract

The influence of polarization crosstalk of Y branch loop on scale factor is analyzed in detail. In the Y branch loop, the scale factor is affected by only the output alignment angle of the PBS. The experiment result shows the range of output alignment angle of the PBS should not exceed from 0.2 to 2.5 over a range from - 40°C to 70°C which corresponds to angle 1.8 at room temperature to make sure the measurement accuracy within ±0.2% from 0 to 100kA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.