To explore the feasibility of the online turbidity meter installed in-line, we have to study the influence of flow velocity on in-pipe turbidity detection. In the laboratory self-designed water circulation system, the correlation between the in-pipe turbidity and flow velocity was studied by altering the water flow rate in the pipe. The results show that the in-pipe turbidity and flow velocity have a benign linear relationship for the slow flow; as the flow velocity increases, the in-pipe turbidity increases slightly but is limited. However, there is no significant correlation between the in-pipe turbidity and flow velocity for the fast flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.