Abstract
The aim of this study was to evaluate changes in total respiratory heat loss during use of a heat and moisture exchanger (HME) in tracheotomized patients. Tracheal humidity and temperature were measured before the application and during use of the HME (plastic foam impregnated with CaCl2), and total respiratory heat loss was calculated. No significant difference was found between the convective heat exchange before and after use of the HME for a 10-minute period. When the HME was placed on the tracheal opening, the evaporative heat exchange and the total respiratory heat loss decreased significantly. The results indicate that passive airway humidification is effective in tracheotomized patients even after a 10-minute period. However, the positive effect on the energy balance of the tracheal mucosa after prolonged use of the HME remains to be proven.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.