Abstract
This study aims the development of photoelectrodes to be incorporated in a photoelectrocatalytic ozonation (PECO) process for tertiary treatment of urban wastewaters, targeting the removal of contaminants of emerging concern (CEC). PECO tests were performed using urban wastewater after secondary treatment fortified with Cefadroxil (CFX, C16H17N3O5S), as target model CEC. Three Nitrogen and Carbon doped TiO2 (CN–TiO2) electrodes were synthesized by anodizing at 50, 70, and 90 V, and calcined. These materials were characterized by X-Ray diffraction and Rietveld refinement, Scanning Electron Microscopy, Diffuse Reflectance Spectroscopy, X-ray photoelectron spectroscopy, chronoamperometry, and electrochemical impedance spectroscopy, to correlate defects with photoactivity. All photoanodes considerably reduced their main bandgaps by the incorporation of C and N species, to enable absorption capacities in the UV region using a Xe lamp. The lowest oxygen vacancy content and largest crystallite size were found for CN–TiO2-70, favoring the reduction of bulk defects that could act as recombination of charge carriers. Therefore, oxygen vacancies affect more the TiO2 photoactivity compared to the crystallite size or the light absorption capacity, confirming that a lower content of vacancies in the material bulk and surface doping significantly influence the activity as detected by Rietveld refinement, DRS, and XPS. The electrochemical techniques confirm that the highest photocurrent was obtained for CN–TiO2-70, whence this photoanode was chosen to carry out the CFX degradation. A point defect model simulating Nyquist plot reveals that the photoactivity depends on the speed to diffuse oxygen vacancies through the TiO2 coating. All abatement processes were followed by high-performance liquid chromatography, and Total Organic Carbon (TOC). At neutral and alkaline conditions, CFX is eliminated to levels below the analytical detection limit after 90 min of treatment (TOC removals of 87 and 91%, respectively), indicating that the coupling between the CN–TiO2-70 photocatalyst and ozone is effective in eliminating the contaminant due to parallel routes forming •OH species. Lower CFX degradation observed at acidic pH (TOC removal of 70%) is assigned to the difficulty of oxidizing protonated CFX species.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.