AbstractIn this study, a two‐fluid nozzle, as, e.g., used in fluidized‐bed or spray drying applications, is comprehensively characterized regarding the spray pattern and droplet size. To analyze the spray cone, the spray cone angle and the radial mass distribution of the nozzle were measured at varied liquid flow rate, spray air pressure, liquid insert bore diameter, and air cap position. Additionally, droplet size distributions were recorded at different spray settings. In general, the overall spray cone and single droplets are significantly influenced by the spray parameters, especially the spray air pressure, as well as the nozzle geometry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.