A cryogenic propellant submitted to heat load during long duration space missions tends to vaporize to such an extent that the resulting pressure rise must be controlled to prevent storage failure. The thermodynamic vent system (TVS), one of the possible control strategies, has been investigated using on-ground experiments with NOVEC1230 as substitution fluid. Results obtained for self-pressurization (SP) and TVS control phases have been reported in a previous work. The unexpected inverse thermal stratification observed during these experiments is analyzed in the present work and related to the influence of noncondensable gases. Noncondensable gases, present inside the tank in the form of nitrogen—ten times lighter than the substitution fluid vapor—generate a concentration stratification in the ullage. Assuming the NOVEC1230 remains at saturation in the whole ullage, the density stratification which results from this concentration stratification can explain the observed inverse thermal stratification.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Thermal Science and Engineering Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.