Abstract

The influence of concrete mixture design and environmental factors on cracking in a continuously reinforced concrete (CRC) pavement was documented on Interstate 90 in Hanson County, South Dakota. A project evaluated three mix designs, which were placed in the eastbound direction in 2005. From the study, it was shown that crack frequency was directly related to the initial concrete temperature as specifically contributed by the aggregate in the mix–and a reduced cement content making a less workable concrete. The study recommends an application of curing compound within 30 min to reduce CRC cracking, and wetting the aggregate stockpiles in hot weather to cool them overnight to reduce concrete temperature. Construction of CRC test sections containing at least 510 lb/yd3 of cement with 112 lb/yd3 (15% cement replaced with 18.75%) Class F fly ash is under way to examine the effects of the rate of early strength gain on cracking.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.