The influence of metal hydride hollow cathode on a Penning ion source operation has been carried out. The feature of investigation is hydrogen injection only due to its desorption from metal hydride under ion-stimulated processes. The regimes of optimal discharge operation in the hollow cathode mode are determined. It has been revealed that the transition to the hollow cathode mode occurs at lower voltages, the discharge works without external gas supply, and the working pressure in the cell is set at the level determined by the discharge current. The supply of a negative bias to the metal hydride hollow cathode weakly affects the features of the emission of axial particles, although it allows the increase of plasma density near the metal hydride hollow cathode.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.