Abstract

A total of eleven loading tests were conducted to study the influence of local corrosion on the behavior of steel I-beams subjected to end patch loading. The test parameters included: corrosion pattern (web corrosion, and flange corrosion), corroded length (100mm, 200mm, and 300mm), corroded thickness (4mm, and 6mm), and length of the bearing plate (80mm, and 160mm). Comparisons have been made between the test results and the predicted strengths using current design codes: AISC, AASHTO, and EN1993-1-5. The test results indicate that the web corrosion has a more detrimental effect than the flange corrosion. The behavior of the steel I-beams (e.g., ultimate load, web deformation, and flange and web's strains) is significantly affected by the corroded thickness of the web. However, this is mainly related to the web corrosion within the flange diffusion range. In general, the web local yielding provisions in AISC and AASHTO give the best prediction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.