Abstract

To investigate the influence of linearly polarized near-infrared irradiation using the Super Lizer trade mark on deformability of human erythrocytes. Not only low-powered laser but also linearly polarized near-infrared beams have some biostimulation effects on various tissues. There were some reports of erythrocyte deformability improved by low-powered He-Ne laser irradiation. Human erythrocyte samples stored for three weeks were adjusted to 30% hematocrit. Erythrocyte deformability presented as the filter filtration rate was measured. There was no difference of the filter filtration rate between control group without irradiation and the group of 125 mJ/cm(2) exposure level at a wavelength of 830 nm. However, the groups of 625 and 1,250 mJ/cm(2) exposure levels at a wavelength of 830 nm showed higher filter filtration rates compared to the control group. Linearly polarized near-infrared irradiation in a range of 625-1,250 mJ/cm(2) exposure level at a wavelength of 830 nm improved deformability of human stored erythrocytes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.