Abstract

We report the influence of absorption line selection on the tomographic results for high-temperature flames by numerical and experimental methods. Different combinations of infrared H2O absorption transitions are utilized with the Tikhonov-regularized Abel inversion to reconstruct the radial distribution of temperature and H2O concentration in a flat flame. It is shown that besides using the mathematical algorithm such as regularization, selecting a line pair with a large Δ E″ (>1390 cm-1) also reduces the reconstruction uncertainty at 300-2000 K. In this study, a proper selection of absorption line pairs reduces the reconstruction uncertainty by 25% at the same level of noise. The line pair of H2O transitions at 4029.524 cm-1 and 4030.729 cm-1 is recommended for the tomography of high-temperature flames at 1000-3000 K, whereas the line pair of 7185.597 cm-1 and 7444.352 cm-1 can be used at 300-1000 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.