Abstract
Although intraoral scanning is highly reliable, little is known about its accuracy in young children with limited mouth-opening ability. To determine the accuracy of intraoral scans based on the degree of mouth opening. To simulate mouth opening in children with primary dentition, three groups (n = 5 per group) were allocated by maximum mouth opening of 30, 37 and 40 mm. After the primary dentition model was connected to a dental phantom, intraoral scanning was performed using iTero and TRIOS4. The scanned files were digitally evaluated. Root mean square values were calculated to assess trueness and precision. iTero showed deviations of three-dimensional trueness of 0.067 ± 0.008, 0.063 ± 0.001 and 0.065 ± 0.005 mm, and TRIOS4 of 0.07 ± 0.002, 0.064 ± 0.003 and 0.066 ± 0.002 mm in the 30, 37 and 40 mm groups, respectively. There were no significant differences in either mouth opening (p > .017) or the intraoral scanners (p > .05). The same statistical results were obtained for precision, with the exception of the 30 mm of mouth opening. Within the limits of this study, limited mouth opening hardly influenced the accuracy of intraoral scanning.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.