The poor radiation hardness of the otherwise excellent x-ray storage phosphor CsBr:Eu2+ constitutes a problem for its commercial application in medical diagnostics. X-ray induced vacancy centers such as M-centers enhance the diffusion of Eu2+ activators resulting in a formation of photostimulated luminescence (PSL) inactive europium clusters or second phases of europium compounds. The present study investigates the influence of Li-codoping on the radiation hardness of CsBr:Eu2+. It is reported that the integration of Li+ into the CsBr:Eu2+ suppresses the generation of M-centers during x-irradiation and thereby partially improves the radiation hardness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.