Abstract

The oxidation performance of NiCrAlY and NiCrMo coatings thermally sprayed by high velocity air-fuel (HVAF) technique has been investigated in a chloridizing-oxidizing environment, with and without a KCl deposit, at 600 °C for up to 168 h. Both coatings protected the substrate in the absence of KCl due to formation of a dense Cr-rich oxide scale. In the presence of KCl, Cl−/Cl2 diffused through a non-protective and porous NiCr2O4 scale formed on NiCrAlY, leading to formation of volatile CrCl3. On the other hand, Mo in NiCrMo stimulated the formation of a more protective Cr-rich oxide scale which increased the corrosion resistance by reducing Cl−/Cl2 diffusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.