Abstract

IntroductionIntraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters.MethodsIntraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e’/a’). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant.ResultsTransmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e’/a’ (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function.ConclusionThe use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG.

Highlights

  • Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion

  • Congestive heart failure (CHF) remains a major public health concern that is associated with markedly increased mortality

  • Diastolic dysfunction has been reported in 44–75% of cardiac surgical patients prior to initiating cardio-pulmonary bypass (CPB) [3,4,5]

Read more

Summary

Objectives

The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. As the influence of IABP on perioperative diastolic dysfunction has not been thoroughly investigated, the goal of this study was to examine whether IABP counterpulsation influences TEE derived parameters of diastolic dysfunction in a population of patients undergoing CABG surgery

Methods
Results
Discussion
Conclusion