Abstract

The permeation properties of concrete are strongly influenced by the degree of saturation of capillary pores. Test results of the Autoclam air permeability index (API) of radiation shielding concrete are presented. Concrete specimens were made with CEM I and CEM III/A cements and special aggregates for radiation shielding: crushed barite, magnetite, serpentine and amphibolite. Two procedures of accelerated drying with simultaneous measurement of moisture distribution in the specimens were proposed. The specimens were tested at different RH levels from a fully saturated state to an oven dried state. The linear relationship between the API and RH was obtained. Effects of heavyweight and hydrogen-bearing aggregates on air permeability index were revealed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.