Abstract
The objective of this study was to determine the maximum allowable initial moisture content (MC) for cross-laminated timber (CLT) walls having both exterior and interior thermal insulation. A laboratory test was conducted, for which four test walls with two different insulation solutions and two different MCs were built. Based on the test results, a simulation model was configured and simulations using the model were completed. The simulation results determined that the maximum allowable initial MC of the CLT panels was 17% for walls insulated additionally from inside with mineral wool and 15% for CLT wall assemblies insulated with polyisocyanurate (PIR). Based on these results, it was concluded that the allowable MC ranges between 8% and 16% for construction timber, and therefore, using a PIR board as interior insulation for CLT walls should be undertaken with caution given the very small margin for error in MC.
Talk to us