Abstract

Statement of problemThe rotational movement of an implant overdenture (IOD) has a negative effect on the perceived masticatory ability of the denture wearer. However, the influence of implant number on the movement of IODs has not been investigated. PurposeThe purpose of this in vitro study was to evaluate the denture movement of mandibular IODs anchored by different numbers of implants. Material and methodsAn edentulous mandibular test model with artificial mucosa and 5 experimental overdentures (N=5) was fabricated. The locator attachment system with blue nylon inserts was chosen for this study. Three implant positions were prepared: anterior midline (1-IOD), bilateral lateral incisor regions (2-IOD), and anterior midline and bilateral canine regions (3-IOD). Vertical loads of 50 N were applied to the mid-anterior region, the left canine region, the left premolar region, and the left first molar region. The vertical and horizontal displacements at the right distal edge and the vertical displacements at the loading point were measured. The displacement values were statistically analyzed using a 1-way analysis of variance and the post hoc Tukey honest significant difference test with the implant number as a factor. In addition, the values of the vertical and horizontal displacements at the distal edge of the overdenture were statistically compared using a paired t test, and the values of the vertical displacement at the distal edge of the overdenture were statistically analyzed by a repeated measures analysis of variance and the post hoc Tukey honest significance difference test with the loading point as a factor (a=.05). ResultsUpon anterior loading, the 2-IOD showed significantly larger vertical displacements at the right distal edge than the 1-IOD or 3-IOD (P<.01). The horizontal displacements at the right distal edge were small compared with the vertical displacements at the same point, although the displacement of the 2-IOD was significantly larger than that of the 1-IOD upon anterior loading (P=.03). The magnitude of the vertical displacement at the loading point of the 2-IOD was significantly larger than that of the 3-IOD upon anterior loading (P<.01). No statistically significant differences were shown under the other conditions for each loading (P>.05). ConclusionsWithin the limitations of this in vitro study, the following conclusions were drawn: During mastication with the anterior teeth, the use of 2 implants for anchoring an IOD increased the rotation of the denture base more than the use of 1 or 3 implants. The horizontal movements of the IODs were small compared with the vertical movements. Denture movement under the occlusal force in the molar region was smaller than that in the anterior region.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call