Abstract

Introduction. Fires in closed premises of production and storage facilities are the most dangerous, because they hold large areas with a significant fire load. The current direction of providing a fire safety system at production and storage facilities in closed premises is to eliminate the conditions of the rapid development of fire and minimizing its effect through the use of fire curtains. This method of fire protection is practically not used in closed premises of production and storage facilities at the present stage. In most cases, fire partitions are used in such situations. Therefore, a topic issue today is the research of limiting the development of fires with the use of fire partitions and minimizing fire effects.Purpose. Investigate the process of spreading the fire in closed premises of production and storage facilities by using fire partitions to limit the speed of fire spread. Problem statement and solution. The following tasks must be solved to provide fire protection of production and storage facilities:1. to investigate the process of fire spread in closed premises of production and storage facilities without the use of fire partitions;2. to investigate the impact of fire partitions use on fire rate.Two possible modes of development fire in the premises are considered to solve the first problem: 1) with the presence of sufficient air (oxygen), with fire occurred in regulated fire load; 2) with insufficient air (oxygen), with fire occurred in regulated ventilation.It is necessary to choose the material and fire partition design accordingly to solve the second problem. The results of experimental studies [11] showed that fire partitions vermiculite-silicate plates can be used for various building structures manufacturing. Closed production and storage facilities structure analysis showed that these premises are constructed in most cases with a grid of columns 9Х12 m.Conclusions and proposals:1) There is only the first mode of fire with sufficient oxygen (air) in closed premises of production and storage facilities with a total area of more than 5000 m2 in the process of fire. The fire that occurred is regulated only by the fire load.2) The use of fire partitions between sections of the premises of production and storage facilities reduces the probability of fire spreading in the premises by about 3 times.3) It is necessary to continue research work in this direction to obtain more significant results of the process of development and spread of fire in the premises of production and storage facilities.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call