Abstract

In service, reinforced concrete structures undergo various stresses inducing cracks. These cracks provide a preferential path for water and aggressive agents penetration into concrete, which compromises the structural durability by accelerating concrete and steel reinforcement deterioration. In this context, durability of cracked concrete has become an important research topic and can be studied through the permeability of concrete. This research project focuses on the influence of the fiber content and steel reinforcement ratio on the water permeability of reinforced concrete. Water permeability tests were carried out simultaneously with a uniaxial tensile loading applied on reinforced concrete prisms made of high performance concrete (HPC), high performance fiber reinforced concrete (HPFRC) and ultra high performance fiber reinforced concrete (UHPFRC). In service conditions, permeability is reduced by 31, 92 and 99 % for fiber contents of 0.75 % (HPFRC), 1.5 % (HPFRC) and 2 % (UHPFRC) respectively compared with conventional HPC. The increase of steel reinforcement ratio from 1.23 to 2.47 % reduced the permeability by 70 % at service loading.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.