Abstract

The influence of several environmental parameters on NACE SSC A tests results was analysed in this study. The effect of dissolved oxygen, pH and partial pressure of hydrogen sulfide (H2S) on corrosion and cracking susceptibility has been experimented. These experiments were done on steel wires used in oil industry. Experiments have proved that the pH value is the most influential parameter on both corrosion and cracking susceptibility of samples. H2S partial pressure also has a negative effect on cracking susceptibility. The dissolved oxygen content appeared as an incriminating factor on corrosion but can reduce the cracking susceptibility of samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.