Abstract
The influence of electrode materials and surface roughness on the discharge homogeneity of F<sub>2</sub> based excimer laser gas mixtures is investigated in a small x-ray preionised discharge chamber. The temporal and spatial evolution of the discharge is monitored by taking photographs of the discharge luminosity with an ICCD camera. It is found that for the same surface roughness, discharges with nickel coated aluminum electrodes are more homogeneous than the discharges using chromium or gold coated aluminum, massive copper, aluminum, brass and steel electrodes. Moreover, the surface roughness of copper electrodes does not have a large influence on the homogeneity of discharges in F<sub>2</sub> doped excimer laser gas discharges.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.