Abstract
The reactor design is a critical factor for the power cost. In this paper, research has been focused on determining the optimization of the reactor design for improving pulsed streamer energy utilization efficiency and reducing power cost. The influence of electrode configuration on energy utilization efficiency of wire-plate DeSO/sub 2/ reactor has been studied. The experimental results show that energy utilization efficiency of reactor improves when increase the number of discharge wire or decrease the wire-to-plate spacing under same conditions such as the parameters of power supply circuit and DC high voltage, and the optimization wire-to-wire spacing is 0.6-1 times the size of the wire-to-plate spacing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.