Abstract

To analyze the torque application on prosthetic abutment screws using different maintenance times, to determine an influence on the removal torque values. A total of 40 external hexagon implants, 40 titanium screws, and 40 customized abutments were used. In group 1, the screws received a torque of 30 N·cm by instant torque application; in groups 2, 3, and 4, torque of 30 N·cm was applied and maintained for 10, 20, and 30 seconds, respectively. Removal torque was performed 10 minutes after torque application. Data were statistically analyzed using 1-way ANOVA and Tukey HSD test (α = 0.05). The mean and standard deviation (±SD) of removal torque values found were 11.61 ± 1.43 N·cm for group 1; 18.64 ± 1.71 N·cm for group 2; 21.62 ± 0.97 N·cm for group 3; and 21.48 ± 1.55 N·cm for group 4. Groups 3 and 4 exhibited statistically higher values than group 2, which demonstrated significantly higher values than group 1 (P < 0.05). A torque of 30 N·cm applied for 20 seconds seemed to be the best option when considering the removal torque values of external hexagon implants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.