Abstract

A cryogenic permanent magnet undulator prototype designed for Chinese High Energy Photon Source Test Facility (HEPS-TF) at Institute of High Energy Physics is constructed and now commissioning. Motion precision of girders is a significant parameter to guarantee gap error so as to avoid phase error and radiation intensity loss. In order to study and minimize girder parallelism errors, RADIA and SPECTRA are used to calculate qualified motion precision. Spring Modules and single motor closed-loop feedback are designed to compensate the errors. Magnetic field is finally tuned to reach specifications. Details of the study and analysis will be presented in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.