Abstract
The aim of this study was to evaluate the photoelastic fringe patterns around two short-wide implants supporting single crowns with different crown-to-implant (C/I) ratios. External hexagon (EH) cylindrical implants (5 × 7 mm) or Morse Taper (MT) conical implants (5 × 6 mm) were embedded individually into photoelastic resin blocks. Each implant received a single metal-ceramic crown, with a C/I ratio of 1:1 or 2:1 (n = 10). Each set was positioned in a polariscope and submitted to a 0.5 kgf compressive load, applied axially or obliquely (30°). The polariscope images were digitally recorded, and based on isoclinal and isochromatic fringes, the shear stress was calculated at 5 predetermined points around each implant. Data were analyzed by two-way ANOVA (α = 0.05). Under axial loading, the stress was concentrated at the crestal region, and there were no differences between C/I ratio or implant types. In contrast, under oblique loading, EH implants showed lower stress values than the MT group and the 2:1 C/I ratio showed higher stress concentration for both implant types (p < 0.05). Moreover, MT implants showed stress distribution through a higher area than the EH implant did, with a tendency to direct the stress toward the implant's apex under oblique loading. MT conical short-wide implants showed higher stress values that were distributed through a higher area directed to the implant apex. The C/I ratio influences the stress distribution only under oblique loading.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.