Abstract

The cross-hole test block test, the acoustic emission characteristics of the system base metal, manual welding and automatic welding for each defect, the research shows that the attenuation of the ultrasonic wave in the base metal and the weld is different, and the attenuation in the weld is greater. Because the welding process causes the coarse crystal structure in the weld, the attenuation of the ultrasonic wave in the weld is increased, and the sensitivity of the weld detection is also increased. Ultrasonic waves pass through the manual weld seam longer than the automatic weld.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.