Abstract

Experimental investigations of the influence of converter feeding the field circuit of a three-phase synchronous generator with a superconducting field winding have been performed. Four converter circuits have been tested: a B6 three-phase bridge, two parallel B6 three-phase bridges, a three-phase bridge with bypass thyristors, and a high-current power-MOSFET converter. Steady-state and transient operation have been tested. There was a special interest in the harmonics generated by the converter circuits and their power dissipation in the low-temperature region. The thermal reaction of the field circuit has also been considered. A method has been developed to prevent the superconducting winding from the quenching in transient operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.