Abstract

In the current study, the impact of C-ratio, convective heat transfer coefficient, and free stream temperature on the maximal cell temperature and temperature uniformity was computationally and statistically examined. Results revealed that the free stream temperature was the main influential factor for the maximal cell temperature for both natural and forced convection conditions while the C-ratio was the most effective parameter for the temperature uniformity for both natural and forced convections. On the other hand, the contribution of the free stream temperature to the maximum battery temperature increased from 63% to 94% when the conditions were changed from natural convection to forced convection. Moreover, the contribution of the C-rate to the temperature uniformity decreased from 89% to 79% when the conditions were changed from natural convection to forced convection. The results obtained from this study are significant in terms of determining which factor should be given more importance under natural and forced convection conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.