Abstract

Lance injected desulphurization become ineffective when injection ports become obstructed. In this work, the difference of the flow fields between single and double hole injection was investigated by numerical simulations. When one of the openings in a T-shaped injection lance is blocked, a dead zone occurs in the ladle over approximately 1/4th of the volume, and there is not an active flow field on the surface of clogging side. To decrease clogging, industrial experiments examining different diameter lances were carried out. The results showed that clogging can be reduced by increasing the injection pressure and optimizing the injection hole diameter to be approximately 10 times the particle size of desulphurizer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.