Abstract

The article is devoted to the results of studies, which have been conducted on parts with electrolytic chromium in order to determine the effect of the coating on fatigue strength of their. The work was performed in observance of standards, which are fixed in GOST RV 2840-001-2008. Samples for the tests were made from standard gas turbine engine compressor blades. We used a VEDS- 1500 electrodynamic vibration stand with an UMK-12K power amplifier to excite vibrations. It has been shown that the minimum endurance limit of 46 kgf/mm2 based on 2 ∙ 107 cycles, established on uncoated parts, didn't decrease during fatigue tests of compressor blades with an electroplated chrome layer. It should be stressed that the influence of the geometry of the chrome-plated part on the reduction of the endurance limit has been established.