Abstract

On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.