Abstract

The Channel Frequency Response (CFR) is an important parameter in the specification of Power Line Communications (PLC) equipment. In this paper, low voltage indoor power cables are investigated and their suitability for PLC operation determined. This is done in terms of their Channel Frequency Response (CFR). Cable parameters such as inductance, capacitance, resistance, length and termination are investigated up to 100 MHz. This work shows cable length and load impedance are the primary factors affecting CFR behavior. Long cables (in the 100's of meters) and low load impedances — lower that the cable characteristic impedance (few Q) can dramatically limit the bandwidth of the CFR. Variances in geometry, dielectric and resistance are only secondary effects and do not affect CFR as drastically as length and load impedance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.