Abstract

ABSTRACT The creep rupture ductility has been investigated for Gr.122 at 550 to 650 oC for up to 112,247.8 h. The obtained results are compared with those for Gr.91 and Gr.92. The degradation in reduction of area (RA) in Gr.122 is similar to that in Gr.92 but more significant than that in Gr.91. The boron nitride inclusions are responsible for the degradation in RA in Gr.92 and Gr.122. The creep ductility parameter λ of Gr.122 decreases with increasing test duration to small values less than 5 at 20,000 h to 30,000 h and then increases steeply to about 20 at long times at 650 oC. The RA and total elongation of Gr.122 decrease with increasing test duration to small values but then turn to increase at 625 oC and 650 oC and long times.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.