Abstract
In this paper, we present the results of an experimental study on the influence of the lateral misalignment between the axes of the annular electron beam and the cavity on the performance of a 1-MW 140-GHz gyrotron. The subject of the study is of practical interest. On one hand, the discrepancy between numerical simulations of the gyrotron performance and experimental results could by partially attributed to the beam misalignment. On the other, it is in practice very difficult to reach the necessary tolerances in series production of high-power high-frequency (>100 GHz) gyrotrons. The problem actually will become more demanding with the increase of the operating frequency of the working mode because the required accuracy scales with the wavelength of the electromagnetic wave. It is shown that a large displacement of the annular beam from the cavity axis may lead to the excitation of a competing mod which is not excited under normal conditions. The excitation of the main mode is observed, however, at a beam-cavity displacement of up to 0.8 mm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.