Abstract

Using a constant tidal volume and ventilatory frequency, anesthetized piglets were ventilated with a new tidal volume ventilator. A short inspiratory time without a pause (10% of breathing cycle) was compared with a longer inspiratory time with a pause (33%) both with and without bronchial obstruction. Mechanics of ventilation, pulmonary ventilation, gas exchange, gas distribution, and lung perfusion were measured. The longer inspiratory time with a pause resulted in lower peak airway and end inspiratory pressures and a higher total compliance. Dead space/tidal volume ratio was reduced and the RQ was increased. While the cranial pulmonary fields were less well ventilated, the right caudal field was better ventilated. In the presence of bronchial obstruction, better alveolar ventilation was achieved when an end inspiratory pause was added. The results emphasize the importance of static end inspiratory tracheal conditions although the tidal volumes were kept unchanged.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.