Abstract

A pulse-jet bag filter, representative of those implemented in waste incineration plants for flue gas treatment, was studied at laboratory scale to evaluate the influence of air humidity on the filtration performance. Several cycles of clogging/unclogging were performed with non-hygroscopic submicronic particles with a nanosized fraction with on-line cleaning at operating conditions as similar as possible to those found in the flue gas treatment of waste incineration plants (150 °C – 73 g/m3 of absolute humidity), and in dry conditions (150 °C).The results revealed a significant influence of air humidity on the bag filter performance: faster increase of bag filter pressure drop during clogging in presence of humidity due to water capillary condensation, lower efficiency of particulate cake unclogging and better collection efficiency of particles between 110 and 300 nm in diameter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.