Abstract

The research of influence of accelerating gap configuration on parameters of a forevacuum plasma-cathode source of a pulsed low-energy (up to 10 keV) large-radius electron beam is presented. An increase in cell sizes of a mesh emission electrode increases electron emission efficiency, but leads to a decrease in electric strength of an accelerating gap. Larger cell sizes of a mesh extractor provide higher electron beam current. An increase in the length of the accelerating gap first leads to an increase in the electron emission efficiency, but when optimal value is reached, a further increase in the length leads to a decrease in the emission efficiency. This optimal length of the accelerating gap is about 25 mm. However, the electron emission efficiency changes relatively small (within 15%). The dependencies of maximum emission current and maximum operating gas pressure on the length of acceleration gap is similar to the dependence for the emission efficiency, but the gap length much stronger influences on these maximum values. Moreover, the optimal length, at which maximum emission current or maximum pressure is provided, is depended on gas pressure (for current) or emission current (for pressure), accelerating voltage and pulse duration.