Abstract

EMT6 mouse mammary tumour cells in vitro were exposed to an almost uniform 1400-gauss magnetic field during or after irradiation with 120 kV X-rays. Exposure of unirradiated control cultures to this field for up to 48 hours did not alter the viability or growth of the cells. Exposure of exponentially-growing cultures to the magnetic field during irradiation did not alter the survival curve. Exposure of exponentially-growing culturesto the magnetic field between two doses of 500 rad of X-rays did not alter significantly the pattern or magnitude of the recovery from sub-lethal damage. Exposure of plateau phase cultures to the magnetic field after irradiation did not alter significantly the pattern or magnitude of recovery from potentially-lethal damage. The effects of a short exposure to an almost uniform magnetic field of this strength on the production and repair of radiation damage appear to be minimal in this system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.