Abstract

Two coincidence techniques for simultaneously obtaining particle size and temperature in a plasma torch are described. The absolute magnitude of scattered laser light is used to determine particle size while particle temperature is determined using a two-colour pyrometer technique. Typical results on alumina particles injected into a 7 kW plasma torch are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.