Abstract

Infectious complications of hemodialysis include bacterial infections caused by contaminated water or equipment, other bacterial infections (including vascular access infections), and bloodborne viruses (primarily the hepatitis B and C viruses). Infections caused by contaminated water and equipment can be prevented by a well-designed water-treatment system, routine cleaning and disinfection of system components, and routine bacteriologic monitoring of dialysis water and dialysis fluid. Standard precautions with additional measures recommended specifically for dialysis centers will prevent transmission of bacteria and viruses from patient to patient. These precautions include routine use of gloves, handwashing, and cleaning and disinfection of the external surface of the dialysis machine and other environmental surfaces. In addition, preventing transmission of hepatitis B virus infection requires vaccination of susceptible patients and staff, avoiding dialyzer reuse, and use of a dedicated room, dialysis machine, and staff members when treating patients chronically infected with this virus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.