Abstract
The inertial response of permanent magnet synchronous generator (PMSG)-based wind energy conversion system (WECS) with virtual synchronous generator (VSG) control (WECS-VSG) is analysed in this paper. The differences between WECS-VSG and synchronisation generator (SG) are focused. For SG, the input active power is constant during inertial response stage. However, due to the control coupling between VSG and the other control function of WECS, the VSG active power reference value will change during the same stage. In order to understand the problem physically, the effective inertia of the WECS-VSG is deduced from the perspective of output equivalence. Based on the analyses of effective inertia, the authors know that the control coupling in WECS-VSG will weaken the VSG inertial response ability. Therefore it is a must to improve the WECS-VGS control realisation in the future study. All the analyses in this paper are verified by simulation results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.