Abstract

Due to the high penetration of renewable energy resources in microgrids (MGs), the grid inertia becomes low which leads to the grid to be vulnerable to large disturbances. The energy storage devices can play an important role to enhance the inertia of MGs. However, due to the high investment cost of storages or their dp/dt limitation, the installed energy storages cannot cover the challenge of high df/dt . A prominent solution to solve the problem is to use the inertia response of the wind generators. However, relatively high second frequency nadir is the main drawback of using the inertia response of the wind generators which may impose an extensive disturbance to MGs. Accordingly, a coordinated operation strategy for MGs between wind generator and hybrid energy storage (HES) system is proposed in this paper. In addition, to improve the inertia response of the MG; providing high-quality communication infrastructures with low delay and increasing the Ultracapacitor capacity have been paid attention. In this paper, the costs of the installed Ultracapacitor and quality of communication services are defined as the operation cost. Guaranteeing enough frequency damping for the MG with low operation cost are two conflict objectives. Therefore, a multi-objective optimization method is used to set the controllers’ values and reduce the operation cost. The results confirmed that the effectiveness of the proposed strategy to control hybrid power storage in coordination with the wind generator and the frequency recovery process is improved. Also, employing the optimum values guaranteed the frequency damping effectively with low operation cost. The Integral Absolute Error (IAE) value and operation cost are reduced by 13.6% and 32%, respectively. Also, the simulation results show that the maximum MG frequency deviation and maximum df/dt is well compatible with different standards in the presence of load perturbations and different wind speeds.

Highlights

  • Nowadays, the design trend of conventional power systems is toward to use small power systems which are called MG

  • Motivated by the mentioned challenges, this paper proposes using power storage units in coordinated with inertia response of wind generators to improve the frequency recovery of the MG

  • A low order model of the wind generator consists of the aerodynamic characteristic wind turbine, the mechanical part and maximum power point tracking (MPPT) unit [68] can be used in the frequency analysis of MGs

Read more

Summary

Introduction

The design trend of conventional power systems is toward to use small power systems which are called MG. The. The associate editor coordinating the review of this manuscript and approving it for publication was S. Use of MGs has been accelerated due to their many benefits such as reliability, resilience, cost savings and increasing grid ability to operate under fault conditions. MGs have the capability to integrate the Distributed Energy Resources (DER), which includes Energy Storage Systems (ESS), controllable loads and communication platforms [1], [2].

Objectives
Results
Conclusion