Abstract
This paper is consecrated to the thermodynamic study and analysis of diffusion-absorption-refrigeration (DAR) plants. The mass and energy balances analysis at the evaporator has allowed to highlight a new and original parameter, which can be used to analyze DAR system performances. It is the ratio of inert gas to refrigerant vapor mass flow rates at the evaporator inlets. This coefficient, which expression has been for the first time deduced mathematically, informs about the quality of the cycle and its performance, which are deeply affected by the growth of the inert gas flow energy expended to drive the refrigerant through the evaporator. The study shows that the coefficient of performance is decreasing with the increase of the mass flow rates ratio. The latter can be also used to find the optimal operating mode for the DAR machine with a specified working fluid.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.