Abstract

In this study, the inert effects of CO2 on the flammability limit and flame propagation of LPG has been investigated experimentally. The observation was done using cubic combustion bomb with the dimension of 500 mm x 200 mm x 10 mm. The results showed that the lower flammability limit (LFL) of LPG-Air mixtures is found to be 2.7% (by volume) and upper flammability limit (UFL) is 8.6% (by volume) with upward propagation of flame. The CO2 dilution effects on the flammability limits have been explored, the limits of flammability was narrowed by adding CO2 and propagation flame was reduced accordingly. The results indicated that to formulate an inflammable refrigerant mixture, using CO2, with substantial hydrocarbon content is not possible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.