Abstract

The fouling of a commercial stainless steel (AISI 316L) during the manufacture of polymeric methylene diphenyl diisocyanate (pMDI) has been studied using laboratory‐based fouling apparatus that simulates commercial production conditions. The goal of the work is to understand the mechanisms behind the corrosion and fouling during isocyanate production with a view to improving process efficiency, not only in this process, but also others using similar plant and processes. Steel coupons were exposed to a solution of pMDI and solid amine hydrochloride, with hydrogen chloride gas being bubbled through the reaction cell. A number of different conditions were investigated, the variables being pMDI concentration, HCl gas flow duration, immersion time and temperature. Following the fouling experiments the coupons were removed from the fouling rig, photographed, and examined by XPS and ToF‐SIMS; principal component analysis was used to extend the ToF‐SIMS analysis to identify organic fouling products. The extent of fouling is shown to be relatively insensitive to pMDI concentration, but significantly influenced by continual HCl flow and increased temperature, features which increase the extent of substrate corrosion thought to be a precursor to the fouling process itself. Both XPS and ToF‐SIMS confirm the formation of various nickel chlorides in the corrosion process. Urea and metal corrosion products are found to co‐exist on certain (random) areas of the coupon surface.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call