Abstract
Tests are performed in an experimental unit on various specimens of ceramic filter screens with slow filtration rates. The hydraulic resistance of materials with filtration rates of 0.5-5.0 cm/sec and mist droplet capture efficiency with a filtration rate of 3 cm/sec are determined.