Until recently, industrial control systems (ICSs) used “air-gap” security measures, where every node of the ICS network was isolated from other networks, including the Internet, by a physical disconnect. Attaching ICS networks to the Internet benefits companies and engineers who use them. However, as these systems were designed for use in the air-gapped security environment, protocols used by ICSs contain little to no security features and are vulnerable to various attacks. This paper proposes an approach to detect the intrusions into network attached ICSs by measuring and verifying data that is transmitted through the network but is not inherently the data used by the transmission protocol—network telemetry. Using simulated PLC units, the developed IDS was able to achieve 94.3 percent accuracy when differentiating between machines of an attacker and engineer on the same network, and 99.5 percent accuracy when differentiating between attacker and engineer on the Internet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.